Product Details:
|
Warranty: | 1 Year, 24 Months | Place Of Origin: | Guangdong,China |
---|---|---|---|
Model Number: | GSA-87V | Himdity Range: | 45~75% |
Usege Range: | LED And Other Luminaries Test | Temperature Range: | 5~50℃ |
Envir. Air Pressure: | 85~106Kpa | Certification: | CE SGS ROHS UL |
High Light: | SGS Thermal Shock Climatic Chamber,106 Kpa Thermal Shock Chamber |
Thermal Shock Chamber Environmental Chamber Climatic Chamber
Thermal shock test chamber is a device used to test the resistance of materials, products or components under different temperature conditions. It can simulate extreme temperature change environments, including low temperature, high temperature and sharp temperature changes.
The thermal shock test chamber usually consists of a test chamber, a compressor and a control system. The test chamber is usually divided into high temperature area, low temperature area and test area, and different temperature and time conditions can be set in these areas through the control system. The compressor adjusts the temperature and humidity in the test chamber by controlling the air flow.
During the test, the tested sample is placed in the test area, and then different temperature and time conditions are set by the control system to simulate different environments. The hot and cold shock test chamber can usually perform multiple cycles, each cycle including high temperature, low temperature and recovery period, to simulate the real use environment.
The durability and reliability of materials, products or components, as well as their performance under different temperature conditions, can be assessed through the testing of thermal shock test chambers. This is very important for manufacturers and R&D personnel as it can help them improve product design and manufacturing processes to improve product quality and durability.
performance | Preheat room | Upper limit preheat temperature | 200ºC | |||||
Heating time | +20~+200ºC≈20min | |||||||
Precool room | Lower limit precool temperature | -75ºC | ||||||
Cooling time | +20~-70ºC≈80min | |||||||
Workroom | Temperature shock range | (-55ºC~-10)~(50~+150ºC) | ||||||
Temperature fluctuation | ≤±0.5ºC | |||||||
Temperature deviation | ≤±2ºC | |||||||
Temperature revert time | ≤5min | |||||||
Temperature revert conditions |
CJ602S3Ⅰ | Condition 1 | sample load: 10kg with plastic package IC;sample exposed: 30min in +125ºC,30min in -40ºC | |||||
Condition 2 | sample load: 10kg with plastic package IC;sampl exposed :30min in +150ºC,5min in ambient temp,30min in -55ºC | |||||||
CJ602S3Ⅱ | Condition 1 | sample load: 20kg with plastic package IC;sample exposed: 30min in +125ºC,30min in -40ºC | ||||||
Condition 2 | sample load: 20kg with plastic package IC;sampl exposed :30min in +150ºC,5min in ambient temp,30min in -55ºC | |||||||
Condition 3 | sample load: 7.5kg with plastic package IC;sample exposed: 30min in +150ºC,30min in -55ºC | |||||||
CJ603S3Ⅰ | Condition 1 | sample load: 10kg with plastic package IC;sample exposed: 30min in +125ºC,30min in -40ºC | ||||||
Condition 2 | sample load: 10kg with plastic package IC;sampl exposed :30min in +150ºC,5min in ambient temp,30min in -55ºC | |||||||
CJ603S3Ⅱ | Condition 1 | sample load: 20kg with plastic package IC;sample exposed: 30min in +125ºC,30min in -40ºC | ||||||
Condition 2 | sample load: 20kg with plastic package IC;sampl exposed :30min in +150ºC,5min in ambient temp,30min in -55ºC | |||||||
Condition 3 | sample load: 10kg with plastic package IC;sample exposed: 30min in +150ºC,30min in -55ºC | |||||||
CJ605S3Ⅰ | Condition 1 | sample load: 10kg with plastic package IC;sample exposed: 30min in +125ºC,30min in -40ºC | ||||||
Condition 2 | sample load: 10kg with plastic package IC;sampl exposed :30min in +150ºC,5min in ambient temp,30min in -55ºC | |||||||
CJ605S3Ⅱ | Condition 1 | sample load: 20kg with plastic package IC;sample exposed: 30min in +125ºC,30min in -40ºC | ||||||
Condition 2 | sample load: 20kg with plastic package IC;sampl exposed :30min in +150ºC,5min in ambient temp,30min in -55ºC | |||||||
Condition 3 | sample load: 10kg with plastic package IC;sampl exposed :30min in +150ºC,30min in -55ºC | |||||||
construction | shell | cooling steel plate,surface spray | ||||||
inner | steel plate | |||||||
refrigeration | insulate | Rigid Polyurethane Foam+extra-fine glass-wool | ||||||
mode | cascade refrigerating compressor | |||||||
compressor | import compressor | |||||||
Cable port(mm) | one on left side Φ50 | |||||||
Controller | color LCD touchscreen display | |||||||
recording equipment | temperature recorder(optional) | |||||||
communication Interface | RS485 interface,RS232 interface | |||||||
Power Supply | AC380V 50Hz Three-phase four-wire + protective earth wire | |||||||
Standard Configuration | A copy of the instruction and test report for the product, A certificate and quality assurance.2 Shelf and 4 shelves . | |||||||
Standards Applied | GJB150.5 |
FQA:
1. who are we?
We are based in Guangdong, China, start from 2021,sell to Southeast Asia(90.00%),North America(10.00%). There are total about 11-50 people in our office.
2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3.what can you buy from us?
Environmental Test Chamber,Rapid Temperature Change Chamber,environmental temperature test chamber,Climatic Testing Chamber,Industrial Test Chamber
4. what services can we provide?
Accepted Delivery Terms: FOB,CIF;
Accepted Payment Currency:USD,EUR,CNY;
Accepted Payment Type: L/C,Cash;
Language Spoken:English,Chinese,Russian
Contact Person: Ms. Kris Zhang
Tel: 0086-0769-85914911