Product Details:
|
Place Of Origin: | Dongguan China | Heating Rate: | Test Room RT→+50℃≤60 Min Pressure Barrel RT→+63℃≤60 Min |
---|---|---|---|
Humidity Range: | 20%~98%RH | Testing Room Capacity: | 60,120,270,480L / Customized |
Temperature Uniformity: | ≤2.0℃ | Controller: | Programmable LCD Touch Screen Casters |
Air Pressure: | 86~ 106Kpa | Brand: | GSKA |
High Light: | UV Weathering Test Chamber,Accelerated Weathering Chamber |
Copper Accelerated Salt Spray Test For Powder Coating Testing Room Capacity270L
The principle of:
Salt spray test chamber can do four tests: neutral salt spray test (NSS), copper accelerated acetate spray test (CASS), alternating salt spray test, acetate spray test (ASS test). Of course, not only do different tests require different solutions, but the design and structure of the chamber may also be different.
neutral salt spray test (NSS) test chamber temperature requirements in (35±2)℃, humidity greater than 95%, fog volume of 1 ~ 2mL/80cm*h nozzle pressure is 78.5-137.3kpa (0.8 ~ 1.4kGF /cm2). In the salt spray test box, the salt water containing (5 g 0.5)% sodium chloride and pH value of 6.5 ~ 7.2 is sprayed through the spray device, and the salt spray is settled on the test parts to be tested, and the corrosion state of the surface is observed after a certain time.
Second, copper accelerated acetate spray test (CASS) is to add copper chloride 2 water to 5% sodium chloride brine on the basis of general salt spray test to make its concentration 0.26g/L, and then adjust the PH with acetic acid to make the PH value of salt spray collection solution 3.1-3.3. (test reference GB/T 10125 artificial atmosphere corrosion test)
Three, the alternating salt spray test is a comprehensive salt spray test (using the alternating salt spray test box to achieve.
Four, acetate spray test (ASS test) is developed on the basis of the neutral salt spray test. It's a solution of 5% sodium chloride with some glacial acetic acid
Technical Parameters:
Inside box size(cm) | 60x45x40 | 90x60x50 | 120x80x50 |
Outside box size(cm) | 107x60x118 | 141x88x128 | 190x110x140 |
Testing room temperature | Salt test (NSS ACSS)35℃±1℃/ Corrosion Test (CASS)50℃±1℃ | ||
Pressure barrel temperature | Salt test (NSS ACSS)47℃±1℃/ Corrosion Test (CASS)63℃±1℃ | ||
Brine temperature | 35℃±1℃ 50℃±1℃ | ||
Testing room Capacity | 108L | 270L | 480L |
Brine tank capacity | 15L | 25L | 40L |
Salt concentration | The concentration of sodium chloride 5% or the 5% concentration of sodium chloride add 0.26g per liter of copper chloride (CuCl2 2H2O) | ||
Air pressure | 1.00±0.01kgf/cm2 | ||
Spray volume | 1.0~2.0ml/80cm2/h (working at least 16 hours, and then take the average) | ||
Testing room relative humidity | 85% above | ||
PH | 6.5~7.2 3.0~3.2 | ||
Spray form | Programmable spray (Including continuous and intermittent spray) | ||
power | AC220V1Φ10A | AC220V1Φ15A | AC220V1Φ20A |
Applications:
The salt spray test chamber is a climate simulation device that tests the corrosion of electronic equipment, metallic material, as well as some surface treatment--coating, galvanizing, organic/inorganic coating, anodizing treatment, rust-proof oil coating, etc. Performance indicators in line with requirements of GB / T5170.8 Electrical and Electronic Products, Environmental Testing Equipment, the Basic Parameters of the Test Method. The salt spray corrosion test chamber according to GB / T2423.17 Electronic and Electrical Products Basic Environmental Test Procedures Test Ka: Salt Spray Test Method for neutral salt spray test can also be used for acetic acid salt test.
We keep good quality and competitive price to ensure our customers benefit ; We respect every customer as our friend and we sincerely do business and make friends with them,no matter where they come from. Each batch of parts is done quality sampling inspection before into the warehouse, and Each product before delivery is tested by the national authoritative third-party inspection agency
Characters:
1. Use special machine structure which can meet temperature and humidity well distribution.
2. Use environment-friendly refrigerant which meets international standard.
3. LCD display screen uses dialog box operating easy and user-friendly.
4. When fault occurs, display failure causes to help troubleshooting.
5. Have safety protection equipment and power failure memory.
6. Connect with computer, recorder(under user needs)
Contact Person: Ms. Kris Zhang