Product Details:
|
Sinusoidal Thrust: | 50(kN) | Maximum Speed: | 1.5(m/s) |
---|---|---|---|
Table Size: | φ500(mm) | Working Environment: | Temperature Range 0~40℃, Humidity≤80% (no Condense) |
Frequency Range: | 5~2500(Hz) | Dimensions: | 1130×920×1080(mm) |
Power Amplifier Output: | 48(kVA) | Power: | AC 380V ±10% 50Hz |
High Light: | Vibration Test Bench,Vibration Test Equipment |
GSKA01 series is an air-cooled electric vibration test system, which has many advantages such as wide frequency, excellent performance, high reliability, small footprint, convenient movement and simple operation. The capabilities of sinusoidal, random, classical shock and compound vibration tests all meet the relevant test standards.
High first-order resonance frequency: the optimal design of the moving ring skeleton structure, especially the weak links such as the traditional structure of the moving ring skeleton force transmission Angle plate, effectively improves the force transmission stiffness. The composite fixing method of adhesive joint and screw connection is adopted to improve the stiffness of the winding and the first-order common vibration frequency of the moving coil.
High reliability of moving coil winding: the new structure and new technology of the strengthening ring of the original moving coil winding greatly improve the reliability of moving coil winding in high thrust, high acceleration vibration, impact and high temperature environment;
Capable of horizontal and vertical testing: Tables with horizontal slides can be used for horizontal and vertical testing. The switching method of two directions is simple and easy to flip;
Full function digital vibration controller: with sine, random, sine plus random, random plus random, classical shock and shock response spectrum test functions.
Technical Specifications:
Model Parameters |
GSKA 70-5K |
GSKA 70-1T |
GSKA 70-2T |
GSKA 70-3T |
GSKA 70-4T |
GSKA 70-5T |
GSKA 70-10T |
GSKA 70-20T |
GSKA 70-30T |
GSKA 70-40T |
GSKA 70-50T |
||
Force (KN) |
5 | 10 | 20 | 30 | 40 | 50 | 100 | 200 | 300 | 400 | 500 | ||
Vibration Direction | Vertical, Horizontal | ||||||||||||
Frequency Range (Hz) |
Sine | 0.1~200 | 0.1~200 | 0.1~200 | 0.1~150 | 0.1~150 | 0.1~130 | 0.1~130 | 0.1~100 | 0.1~100 | 0.1~80 | 0.1~80 | |
Random | 0~300 | 0~300 | 0~300 | 0~300 | 0~200 | 0~200 | 0~200 | 0~150 | 0~150 | 0~150 | 0~150 | ||
Max. Load (kg) | 100 | 200 | 400 | 600 | 800 | 1000 | 1500 | 3500 | 5000 | 7000 | 8000 | ||
Table Size (mm) |
600× 600 |
800× 800 |
1000× 1000 |
1200× 1200 |
1500× 1500 |
1800× 1800 |
2000× 2000 |
2500× 2500 |
3000× 3000 |
||||
Max. Displacement (P-P) (mm) |
100 | ||||||||||||
Max. Velocity (m/s) | 1 | 0.6/1 | 0.6 | ||||||||||
Max. Acceleration (g) |
5 | ||||||||||||
Weight (kg) |
1500 | 1800 | 2000 | 3000 | 3500 | 4000 | 5000 | 6000 | 8000 | 9000 | 10000 | ||
Installation Condition |
Working Environment |
Temperature 0~40℃,Humidity ≤80% (no condense) | |||||||||||
Power Supply (kVA) |
AC380V 18KVA |
AC380V ±10% 22KVA |
AC380V 30KVA |
AC380V 40KVA |
AC380V 45KVA |
AC380V 55KVA |
AC380V ±10% 90KVA |
AC380V 110KVA |
AC380V ±10% 130KVA |
AC380V ±10% 150KVA |
AC380V ±10% 170KVA |
||
Floor | Foundation-free, the cement floor shall be leveled and the working diatance of 800 ~ 1000mm shall be reserved around the equipment | ||||||||||||
Cooling Method | Air Cooled | Water Cooled | |||||||||||
Standards | ISTA1~7 MIL-STD-810 IEC 60068-2 ASTM D4728 |
Customer Support Services:
Ø Installation
Ø Training (Training customer employees)
Ø Calibration
Ø Preventative maintenance
Ø Replacement parts
Ø Assistance via phone or internet