Product Details:
|
Place Of Origin: | Dongguan China | Customized Support: | OEM |
---|---|---|---|
Cold Exposure Range: | +20ºC To -80ºC | Heat-up Time: | RT To 180ºC≤20min |
Brand Name: | GSKA | Power: | 220V , 50Hz |
Temperature Fluctuation: | ±0.5ºC | Test Temperature Range: | -40ºC To +150ºC Optional -70ºC/-80ºC To +150ºC/+180ºC |
High Light: | Temperature Test Chamber,Climate Test Chamber |
Pre-Heat Limit +200ºC Thermal Shock Chambers Automatic Programmable
Features:
1. Perfect appearance and easy to operate.
2. Imported LCD English microcomputer temperature controller, with high memory capacity, can save 100 programs, max 9999 cycles,each cycle max time 999hrs.
3. Two chamber structures, high temperature chamber and low temperature chamber, control automatically, stay and switch time adjustable.
4. Perfect protection alarm functions: short-circuits, Leakage, over temperature of work chamber; compressor over pressure, over load, short water…
5. Control interface will display alarm reason and provide check methods, machine has emergency stop button.
6. Cold and hot shock temperature recover within1 minute, which complies with MTL, IEC, JIS, GJB and other international standards.
High temperature chamber:
1, Including three parts: heater, draught fan and air duct valve
2, Draught fan cyclically stirs hot air through heater
3, The basket with testing product drive to high temperature range when doing high temperature impact test.
Low temperature chamber:
1, Including four parts: evaporator, energy storage piece, draught fan and air duct valve
2, Draught fan cyclically stirs cold air through evaporator and energy storage piece.
3, The basket with testing product drive to low temperature range when doing low temperature impact test.
Specifications:
Model No. | GSKA-80 | GSKA-100 | GSKA-150 | GSKA-250 | GSKA-480 |
Interior(cm) (WxHxD) | 50x40x40 | 50x45x50 | 60x50x60 | 70x60x70 | 80x80x80 |
External(cm) (WxHxD) | 165x180x175 | 170x180x180 | 180x180x200 | 190x180x240 | 205x225x215 |
Specimen load capacity | 5kg | 5kg | 10kg | 15kg | 20kg |
Test temperature range | -40ºC to +150ºC optional -70ºC/-80ºC to +150ºC/+180ºC | ||||
Hot exposure range | +50 ºC to 200ºC | ||||
Cold exposure range | +20ºC to -80ºC | ||||
Pre-heat limit | +200ºC | ||||
Pre-cool limit | -80ºC | ||||
Temperature fluctuation | ±0.5ºC | ||||
Temperature deviation | ≤±2.0°C | ||||
Heat-up time | RT to 180ºC≤20min | ||||
Pull-down time | RT to -65ºC ≤55 min. | ||||
Temp.recovery time | Within 5 min. | ||||
Transfer time | Between hot and cold chamber within 10seconds | ||||
Specimen baskets | Shelf brakets on two levels of fixed location | ||||
Refrigeration system | Mechanical cascade refrigeration system | ||||
Condenser | Air-cooled, cold accumulator | ||||
Ambient temp.range | RT to 35ºC | ||||
Power supply | AC 380V @50Hz three phases | ||||
Cooling method | Optional air-cooled or water cooled, depends on specimen and inner size | ||||
Cooling tower | Water cooled model type is requested. |
Customer Support Services:
Ø Installation
Ø Training (Training customer employees)
Ø Calibration
Ø Preventative maintenance
Ø Replacement parts
Ø Assistance via phone or internet
Ø On-site diagnosis and repair/online diagnosis and repair
Contact Person: Ms. Kris Zhang
Tel: 0086-0769-85914911