Product Details:
|
Hot Chamber Temp.Range(℃): | +50/+200 | Temperature Fluctuation: | ±1.0℃ |
---|---|---|---|
Customized Support: | OEM | Condenser: | Water-cooled Condensing Agent |
Impact Recovery Time: | (-40)℃~(+150)℃≤5min | Temperature Uniformity: | ±2.0℃ |
Power: | 220V , 50Hz | Keyword: | Thermal Shock Chamber |
High Light: | Temperature Test Chamber,Climate Test Chamber |
SUS304 Cycling Thermal Shock Chamber Anticorrosive With 2 Zones
The thermal shock test chamber is used for testing non-heat dissipation test samples and low heat dissipation test samples. For the test of heat dissipation test samples, the heat dissipation power should not exceed the temperature control cooling capacity of the refrigeration system of the test chamber, otherwise it will affect the temperature conversion speed and capacity of the thermal shock test
chamber. It is recommended that the heat dissipation of the test samples be less than 300W.
The thermal shock test hamber suitable for examining the ability of the whole machine, components,parts and other components to withstand sharp changes in temperature. The temperature impact test can understand the impact of the test sample once or repeatedly due to temperature changes. The main parameters affecting the temperature change test are the high and low temperature values in the range of temperature change, the holding time of the sample at high and low temperature, and the number of cycles of the test, etc.
Temperature range | A.high-temperature : +60 degree to +150 degree |
B.low-temperature : -10 degree to -40 degree | |
Control temperature | ±2 degree |
resolution | 0.01 degree |
Heating time at high-temperature region | From RT to 150 about 35min (RT is from 5 degree to 30 degree). |
Cooling time at low-temperature region | From RT to -40 degree about 50min (RT is from 5 degree to 30 degree) |
Moving time and temperature recover time | A. testing bastet moving from high-temperature to low-temperature spend 10sec |
B.after exchanging the temperature,the tempreature recovery time: 3min to 5min (Stabilization time ≥ 30min) | |
Device noise | Below 75dB. |
Weight | 10Kg |
Testing region(hot and cold) | 50cm(W)*50cm(H)*50cm(D) |
Outside size | 140cm(W)*180cm(H)*142cm(D) |
Testing basket size | 30cm(W)*40cm(H)*30cm(D) |
Inside material | SUS#304 Cold-Heat-resistant stainless steel |
Outside material | SUS#304 Cold-Heat-resistant stainless steel |
Insolution material | High-density glass wool and high strength PU foam insulation |
Anti-sweat structure | insulation layer and door micro-thermal anti-sweat |
Expansion | Heat reach 300 degree,cold reach -100 degree |
Service:
1. Device installation;
2. Equipment Operation Test Technology training;
3. Equipment Calibration;
4. Daily maintenance and maintenance of equipment
5 Free technical training for visiting factories
6 24-hour Online contact
7 Free software upgrades
Structure:
Integral, the top is preheating tank (with test chmaber door), the bottom is precooling tank, the studio is preheating tank and precooling.The mobile metal pod is between the slots, the electric control cabinet and the refrigeration unit are behind, and the main control interface is located in the test.Square before the inspection door. The gate is opened in the width direction. Each slot area is equipped with an independent circulating air duct system: wind motor,Centrifugal fan blade, vane.
Contact Person: Ms. Kris Zhang